Syntha Lab RU

Cp and Cpk: process capability

Cp compares the tolerance width with the process spread, Cpk also accounts for the mean shifting towards a tolerance limit.

Production and import

Open interactively →

Formula

Cp = (upper − lower) ÷ 6σ; Cpk = min(upper − mean; mean − lower) ÷ 3σ

How to read

The rules of thumb 1 and 1.33 are illustrative: the required value is set by the quality agreement. It can be counted only for a stable process.

Where it is discussed

Topics

Calculations

Other terms in the group

Open interactively →