Usable hall area, running meters and display capacity: coverage of the need, density, sales per meter and zone rotation
From the hall area, the service zones (fitting rooms, till, stock on the floor) and the share of aisles it counts the usable selling area; from a table of fixtures (rails, racks, tables, shelves with the number, the display meters and the density) it counts the running meters and the display capacity in units and compares it with what must be shown. It gives the coverage, the surplus or the shortage, the density per square meter, the sales per square and per running meter a month and, from the zone rotation cycle, the number of zones per week, the hours of work and their cost. Set the density per running meter from your own planograms; the default values are illustrative.
At a glance
- What question does it answer?
- How much usable area and how many running meters the hall gives, how many units the display holds and whether it is enough for the need, what the density is and how much a regular change of the display costs.
- What data is needed?
- The hall area, the service zones and the share of aisles by the store plan.
- How to read the result?
- Example at the default values (a 120 m² hall): the usable area is 58.5 m² (48.8% of the hall); 47.2 running meters, a capacity of 461 units against a need of 400: coverage 115.2%; a density of 7.9 units per m²; sales of RUB 82,051 per m² and RUB 101,695 per running meter a month; rotation of 2 zones a week, 26 h a month, RUB 11,700. Example on the default values: Usable selling area, m²: 58.5; Share of usable area in the hall: 48.8%; Running meters of display: 47.2; Running meters per 10 m² of usable area: 8.1. The figures are illustrative: enter your own to see your result.
Why and how to reason
The display competes for area and the area is divided not as it seems by the plan. In a 120 m² hall the service zones (fitting rooms 12, the till 8, stock on the floor 10) take 30 m², the aisles at a share of 35% of the remaining 90 m² take 31.5 m² and the usable selling area is 58.5 m², that is 48.8% of the hall. The fixtures give running meters: 8 wall rails of 2.4 m, 6 racks of 3 m (both sides), 5 tables of 1.2 m and 4 shelves of 1 m are 47.2 m. Multiplying the meters by the density (9, 10, 14 and 6 units per meter) gives a capacity of 461 units against a need of 400: coverage 115%. Sales of RUB 4.8m a month give RUB 82,051 per usable square meter and RUB 101,695 per running meter. Rotating 8 zones in 4 weeks is 2 zones a week, 26 hours and RUB 11,700 a month.
When to use it
Apply when planning a new store or a corner, changing the season and redistributing meters between categories. The density per meter is set by your planogram and the calculation does not determine it. It does not assess visibility and conversion by zones: for this there is the productivity of a meter by zones. For footwear count shelves and pairs, for accessories showcases and hooks, for children’s add low display and aisles for prams.
How to read the result
First the coverage: below 100% means that the display does not hold the need and the depth of display or the number of SKUs must be cut or fixtures added; 115% means a reserve of 61 units. Then the density per usable meter (7.9 units per m²): the higher it is, the greater the risk of hiding goods. Compare the sales per meter between zones and stores in one way. Compare the cost of rotation (RUB 11,700 a month) with the effect of refreshing: do not break the display without a reason. The next step: redistribute the meters by the zone productivity index and check the execution of the planogram in the stores.
Common mistakes
They count the whole hall area as usable. They cut aisles for the sake of the display: the customer does not enter cramped zones. They take the capacity for a goal and stuff the fixtures to the limit. They take the density from another store and not from their own planogram. They forget the cost of rotation hours and do not include them in the staff schedule.
What data is needed?
- The hall area, the service zones and the share of aisles by the store plan.
- Fixtures: the number, the display meters and the density by planograms.
- The need for display, sales per month, the number of zones and the rotation cycle.
Inputs
| Field | Unit | Value in the example | Meaning |
|---|---|---|---|
| Selling hall area | m² | 120 | The hall area by the plan, in square meters, without the storage rooms behind the hall. The example value is illustrative. |
| Fitting rooms | m² | 12 | The area of all fitting rooms with the passage to them. The example value is illustrative. |
| Till and packing | m² | 8 | The area of the till zone and the packing table. The example value is illustrative. |
| Stock on the sales floor | m² | 10 | The area taken by stock in the hall: open shelves and replenishment. The example value is illustrative. |
| Share of aisles and waiting zones | % | 35 | What share of the area less the service zones is taken by aisles, the space in front of fixtures and stopping zones; set by your layout. The example value is illustrative. |
| To be shown on the display | units | 400 | How many units of goods you plan to keep on the display in the hall: by the planogram and the depth of display. The example value is illustrative. |
| Store sales per month | ₽ | 4,800,000 | The hall revenue without VAT per month: the sales per meter are counted by it. The example value is illustrative. |
| Display zones | units | 8 | Into how many zones the hall is divided for changing the display: a wall, islands, a table, the window. The example value is illustrative. |
| Rotation cycle | weeks | 4 | In how many weeks you want to refresh the display of all zones in a circle; your policy. The example value is illustrative. |
| Hours to change one zone | h | 3 | Staff time to rearrange and check one zone. The example value is illustrative. |
| Cost per hour | ₽ | 450 | The cost of an hour of an employee’s work with payroll taxes. The example value is illustrative. |
How it is calculated
| Step | Formula |
|---|---|
| Usable area | (hall − fitting rooms − till − stock) × (1 − share of aisles) |
| Meters | Σ pieces × meters per piece |
| Capacity | Σ pieces × meters × density; coverage = capacity ÷ need |
| Sales | revenue ÷ usable area; revenue ÷ running meters |
| Rotation | zones per week = zones ÷ cycle; hours per month = zones per week × hours per zone × 52 ÷ 12 |
Worked numbers
Default values from the app; in the interactive version you enter your own.
- Usable selling area, m²
- 58.5
- Share of usable area in the hall
- 48.8 %
- Running meters of display
- 47.2
- Running meters per 10 m² of usable area
- 8.1
- Display capacity, units
- 461
- To be shown, units
- 400
- Coverage of the need by the capacity
- 115.2 %
- Surplus (+) or shortage (−), units
- 61
- Units per square meter of usable area
- 7.9
- Sales per m² of usable area per month
- 82,051 ₽
- Sales per running meter per month
- 101,695 ₽
- Zones to rotate per week
- 2
- Hours of rotation per month
- 26
- Cost of rotation per month
- 11,700 ₽
Data as a table
| Measure | Area, m² |
|---|---|
| Fitting rooms | 12 |
| Till | 8 |
| Stock on the floor | 10 |
| Aisles | 31.5 |
| Usable area | 58.5 |
Data as a table
| Measure | Capacity |
|---|---|
| Wall rail | 173 |
| Island rack (both sides) | 180 |
| Table or unit with folded goods | 84 |
| Shelf (footwear, bags, accessories) | 24 |
Display by fixture
| Fixture | Meters | Capacity, units | Share of capacity |
|---|---|---|---|
| Wall rail | 19.2 | 173 | 37.5 % |
| Island rack (both sides) | 18 | 180 | 39.1 % |
| Table or unit with folded goods | 6 | 84 | 18.2 % |
| Shelf (footwear, bags, accessories) | 4 | 24 | 5.2 % |
The calculation: the usable area = (hall − fitting rooms − till − stock on the floor) × (1 − the share of aisles); the capacity = number × meters × density by type of fixture. The density per running meter is set by the planogram: the higher it is, the lower the visibility of every unit, so the capacity is an upper bound and not a goal. Compare the sales per meter between zones (see the productivity of a meter by zones) and not with market averages. For footwear the meters are counted by shelves and sizes, for accessories by showcases and hooks, for children’s low display and aisles for prams are added.
Nuances and limits
- Counting the whole hall area as usable: fitting rooms, the till and aisles do not sell.
- Raising the density to the limit: goods stop being visible and the sales per meter fall.
- Forgetting the cost of rotation: changing the display eats staff hours.